Published
Public on Status PagePost-Incident Review: EU-West Edge Ingestion Transit Degradation
Postmortem for Elevated Ingestion Latency on EU-West Monitoring Edge
Created by Incident Response Team•Aug 20, 2026•Published Aug 18, 2026•Resolved Aug 18, 2026
Executive Summary
Between 19:51 and 20:15 UTC, the EU-West ingestion cluster experienced transient latency spikes caused by fiber degradation on a primary European transit provider. Traffic was re-routed via secondary edge tunnels. All queued payloads were processed with zero data loss.
Root Cause Analysis & Contributing Factors
Identified Contributing Factors
No specific contributing factors tagged.No 5-Whys root cause analysis recorded for this incident.
Root Cause Analysis Narrative
BGP route flap and localized packet loss on primary transatlantic transit link between London edge proxies and Frankfurt core ingress cluster.
Mitigation & Resolution Summary
Automated failover engaged backup transit routes via Amsterdam IX. Latency normalized to <15ms baseline.
Lessons Learned & Future Resiliency
Edge failover detection threshold reduced from 90s to 30s to accelerate future transit provider degradation responses.